Skip to content
Free Shipping USA Wide | PRICE BEAT GUARANTEE | Contact Us For Deals
Free Shipping USA Wide | PRICE BEAT GUARANTEE | Contact Us For Deals
Free Shipping on All Orders
Price Beat Guarantee
Live Customer Support
Over 5,000 Fireplaces Sold
Free Shipping on All Orders
Price Beat Guarantee
Live Customer Support
Over 5,000 Fireplaces Sold

Buck Stove Model 34 Vent Free Fireplace - Manhattan

SKU
Sale Sale
Original price $2,538.75
Original price $2,538.75 - Original price $2,538.75
Original price $2,538.75
Current price $2,031.00
$2,031.00 - $3,655.00
Current price $2,031.00
  • #1 Authorized Dealer
  • $0 Sales Tax On Your Order (WY excluded)
  • FREE SHIPPING - Free & Fast Shipping on All Orders
  • Questions? Contact Us Now via Live Chat or Call.
  • Questions? Call an Expert Now +1 (334) 246-4045
Fuel Type: Natural Gas
Mantel Color: No Mantel
Add on: No Trim Kit
No Sales Tax

$0 Sales Tax on Your Order (excl. WY)

Lowest Price Guaranteed

If you find a Lower Price Online we will Beat it!

Need Help? Our Experts are Here to Help

DESCRIPTION

This versatile fireplace will easily bring you warmth and beauty.

  • Minimum Fireplace Dimensions: 29 1/2"W x 24" H x 12" D (for installation into existing wood burning fireplaces)
  • Output BTUs/Hour: 33,000
  • Efficiency: 99.9%
  • This model comes with a heat activated, variable speed 85 CFM blower.
  • Features a reliable standing pilot ignition system that can work with a remote control or thermostat.
  • Works during power outages.
  • This model comes equipped with an oxygen depletion sensor for added safety.
  • This model IS approved for use in manufactured/mobile homes.

This fireplace can either be inserted into and existing fireplace or built into a wall with one of many great mantel options. This fireplace can truly do it all. With 33,000 BTUs of ventless heat it also make your life incredible easy.

The Model 34 ZC Manhattan is Buck Stove's most popular vent-free fireplace. The Model 34 ZC Manhattan can be installed into a mantel cabinet as a new fireplace addition or into an existing wood burning fireplace as an insert. At 33,000 BTUs and burning 99.9% efficient it makes for a great zone heater that will supplement your heating system. Standard features include an 85 CFM factory installed variable speed blower and a reliable standing pilot ignition system that can work with a remote control or thermostat.

Disclaimer - Some states, cities, and/or municipalities have restrictions around vent-free gas fireplaces. It is the responsibility of the customer to ensure you are following all laws & regulations in your area regarding vent-free fireplaces. For example: California does not allow vent-free appliances, Colorado does not allow vent-free appliances in some areas due to altitudes, and Massachusetts does not allow vent-free appliances in bedrooms or bathrooms.

PRODUCT SPECIFICATIONS


Buck Stove Model 34ZC Vent Free Gas Fireplace Or Insert- Manhattan
Weight (in lbs) 104
Brand/Manufacturer Buck Stove
Included Items 85 CFM Heat Activated, Variable Speed Blower
Heating BTU 33,000
Maximum CFM 85 CFMs (Included Blower)
Venting Type Vent Free
Efficiency 99.9%
Amperage Requirement 1.1 Amps (Included Blower)
Type Built-In Fireplace, Brick & Stone Fireplace Insert, Mobile Home Approved
Fuel Type Propane, Natural Gas
Certification CSA
Size Range 30" - 39" Wide
Area Heated 1000 - 1499 Sq. Ft
Fireplace Style Contemporary, Traditional
Minimum Fireplace Dimensions 29 1/2"W x 24" H x 12" D
Height 23 3/4"
Width 34"
Depth 16"
Warranty 5 Years
Resources You will need Adobe Acrobat Reader to view PDF documents.
Safety Information PROPOSITION 65 WARNING

 

Make your living area, cozy with the Model 34 Manhattan

 

MODEL 34 MANHATTAN MANUAL

Shipping Information

FREE SHIPPING To All US States On This Item - (Excluding Puerto Rico, Hawaii, Alaska)

Lead Time - Items Usually Ship within 2-3 Business Days (Contact us for ETA's)

Our Shipping Partners:

Shipping Partners

We partner with the most reliable freight companies in the USA to ensure your order arrives safe and in a timely manner.

Your Item will ship from warehouses all across the United States to ensure fast and efficient delivery times for our customers.

If there are any delays regarding your product shipment, we will let you know in advance. 

Order Confirmation:

As soon as you place your order, you will receive an order confirmation e-mail. (please allow a few hours for this to come through in some cases) This means that we have received your order in our system and pre-authorized your credit card for the purchase. 

As soon as we receive your order, we automatically reach out to our suppliers to confirm that it is in stock and available for immediate shipment. 

If your item is on backorder or unavailable, we will void the pre-authorization and reach out to you via e-mail.  If your item(s) are available for immediate shipment (within 5 business days), we will process the charges and submit the order for shipment.

Order Shipment:

If your order is in stock and we process the charges to your credit card, it will ship within five business days from the date of your order.  We will send you tracking information within 24 hours of your order leaving the warehouse to the e-mail address you provided when checking out.  If you do not receive tracking information from us within six business days of your order, feel free to follow up with us at sales@generationecostore.com

No Shipping outside the USA. (Some exceptions apply - if the website permits you to check out and enter your shipping address, you will receive your order. Some products in particular are available in Canada).

Shipping Options

Our base "Curb-side" Pickup shipping is always completely free! This option usually takes between 5-15 days to arrive at your doorstep, after you have submitted your order.

Threshold Shipping: This involves the item being brought onto your porch, or into a sheltered/garage area. 

Double-Check Your Address

To ensure that your package is properly delivered and that you receive your package within the time frames we advertise, please
make sure that your address is correctly entered and includes all relevant and/or required information. The use of correct
abbreviations, street numbers, building or apartment numbers, and route information (if applicable) is critical for ensuring
timely delivery. 
We do not take responsibility for lost, misplaced, or incorrectly delivered shipments if the address information
provided is incorrect or incorrectly entered at the time of purchase
.

Damages

Please inspect the packaging of your item(s) when they arrive, if you notice any damage, you should make note of it when signing for delivery.  If your item(s) do arrived damaged please send photos of damage, box and SKU, along with a brief description of the damage to info@generationecostore.com and we will process an insurance claim on your behalf. Photos and videos must be sent for freight damage within 24 hours of arrival or the freight damage claim will not be valid. Any punctures, or visible signs of exterior damage must be reported within 24 hours.

Buck Stove Warranty

PRODUCTS COVERED

This warranty covers the new Buck Stove heating unit, so long as it is owned by the original purchaser, including optional and standard accessories purchased at the same time, subject to terms, limitations, and conditions herein set out.

PRODUCTS NOT COVERED
  • This warranty does not cover the following: Glass, Refractory Material, Firebrick or Gaskets.
  • This Warranty will not cover any damage and/or failure caused by abuse or improper
    installation of the products covered.
WARRANTY TIME PERIODS

(A)Period I
For one year from the date of purchase, NBC will replace or repair, at its option, any
part defective in materials or workmanship. The costs of parts only are included. The
customer pays any labor or transportation charges required.
Thereafter,

(B) Period II
For the period after the first year from the date of purchase and extending for five years as long as the Buck Stove is owned by the original purchaser, NBC will repair or replace, at its option, any part defective in materials or workmanship, with the exception of, electrical motors, wiring, switches, components, optional and standard accessories, and all parts not permanently attached to the heating unit. Parts not permanently attached to the heating unit are defined as those items designed to be removed from the stove, including those removable with common hand tools. The costs of parts only are included. The customer pays any labor or transportation charges required. 

PROCEDURE

Should you feel that your BUCK STOVE is defective, you should contact any Buck Stove
dealer for the name of your nearest authorized Buck Stove service representative, who will instruct you on the proper procedure, depending on which Warranty Time Period (Period I or Period II) applies.

If for any reason you are dissatisfied with the suggested procedures, you may contact us in writing at:

New Buck Corporation
Customer Service Department
P. O. Box 69
Spruce Pine, NC 28777
Email: info@buckstove.com

Buck Stove FAQs

I have a catalytic combustor in my wood stove. Can I clean it & how often does this need to be done?

After the first burning, the combustor should have a light gray powder-like appearance. Should the combustor's cells become masked with fly-ash, use a paintbrush or soft-bristle brush and dust the combustor gently. Never use anything abrasive to clean the combustor. A vacuum cleaner may be used, but never use high-pressured air to blow the cells free of any build-up. Any cell blockage can be removed with the use of a pipe cleaner or cotton swab. Should the combustor become masked with soot or creosote, it is possible to burn the accumulation off by opening the by-pass and building a hot fire. Once the hot fire is created, close the by-pass halfway and burn for 30-60 minutes with the bypass in this position. Applied Ceramics suggests checking and cleaning the combustor before each burning season begins, if necessary.

How do I know if my catalytic combustor needs to be replaced?

The catalytic combustor has a six-year life expectancy when used according to the stove owner’s manual. Although, some combustors have operated with efficiency for as high as ten years, the combustor’s life is based on the stove operator, maintenance, fuels used, and the stove manufacturer’s design.

I need a piece of glass for my double door stove and I don’t know what model it is.

The double door glass kit fits the Models 26000 Old Buck (Little),  27000 Old Buck (Regular), and 28000 Old Buck (Big) and consists of the following: 2 pieces of 6 ½” x 9” glass and 2 gaskets for the glass.

My glass has a black film on it. How can I clean it?

You can clean your glass by using an oven cleaner and paper towels or razor blade. You can also make a solution of vinegar and water.

I would like to replace the gasket around my door. What do I need?

Depending on your model, you need door roping and/or ash bar wicking. You will also need a 2.8 oz. tube of high temperature silicone.

I have an older Buck Stove and I would like to convert it to a freestanding stove. Is this possible?

Yes, it is possible. You will need a stack and a pedestal to do so. First, you must determine which model you have. To do so, measure the rectangular opening on the top of the unit. If the opening is 13¾” x  3¼,” you have either a Model 26000 Old Buck (Little) or a Model  27000 Old Buck (Regular). Order part # FA 260421 for the stack and part # FA P4171B for the pedestal. If the opening measures 16” x 3¾,” then you have Model 28000 Old Buck (Big). Order part # FA 280421 for the stack and part # FA P4171B for the pedestal.

I have a Buck Stove with a 3-speed thermostat. It only works on high. Can it be it 3 speeds again?

After the first burning, the combustor should have a light gray powder-like appearance. Should the combustor's cells become masked with fly-ash, use a paintbrush or soft-bristle brush and dust the combustor gently. Never use anything abrasive to clean the combustor. A vacuum cleaner may be used, but never use high-pressured air to blow the cells free of any build-up. Any cell blockage can be removed with the use of a pipe cleaner or cotton swab. Should the combustor become masked with soot or creosote, it is possible to burn the accumulation off by opening the by-pass and building a hot fire. Once the hot fire is created, close the by-pass halfway and burn for 30-60 minutes with the bypass in this position. Applied Ceramics suggests checking and cleaning the combustor before each burning season begins, if necessary.

I have a wood stove and want to make it gas. Can I do this?

No, we do not recommend doing this. If you changed from wood to gas, it would not only void the warranty of the gas log set, but you run the risk of damaging gas components in the log set itself and damaging your home.

My wood stove has developed a crack in the top. Can this be repaired?

Yes, it can be fixed. Buck Stove repairs units during the summer months. Please email us at hello@generationecostore.com or call us at +1 323 768 0928 for further directions.

Regarding gas valves, what is the difference between a Millivolt and Modulating unit?

A Millivolt unit has the capability of using a remote control or wall thermostat to regulate the temperature setting. Whereas, the temperature of a modulating unit is controlled by changing the knob setting on the unit itself.

Should I purchase a catalytic or non-catalytic unit?

Normal rule is, for a primary heat source, choose the catalytic unit. For supplemental heating, choose the non-cat unit. Catalytic units have efficiency rating of 72%. There is more maintenance with a catalytic unit. At some point, depending on how you operate the unit and the type of wood burned, you will probably need to replace the  catalyst. Non-catalytic units have an average efficiency rating of 63%, which is quite high for a wood burning unit. There is not a big price difference between catalytic and non-cat stoves.

MORE ABOUT A CATALYTIC UNIT

WHY DO COMBUSTORS NEED REPLACED?

THERMAL SHOCK – OCCURS WHEN REFUELING WITH WOOD CONTAINING MOISTURE EITHER ON IT OR IN IT. MOIST SMOKE IS SENT TO THE COMBUSTOR WHEN THE BY-PASS IS CLOSED AND THE RESULTS ARE THERMAL SHOCK AND  CRACKING OF THE SUBSTRATE. A CONTINUAL PRACTICE OF THIS WILL CAUSE THE COMBUSTOR TO DETERIORATE. 

    FATIGUE – THE CATALYTIC COMBUSTOR HAS A SIX-YEAR (6) LIFE EXPECTANCY WHEN USED ACCORDING TO THE STOVE OWNER’S MANUAL. ALTHOUGH, SOME COMBUSTORS HAVE OPERATED WITH EFFICIENCY FOR AS HIGH AS TEN YEARS, THE COMBUSTOR’S LIFE IS BASED ON THE STOVE OPERATOR, MAINTENANCE, FUELS USED, AND THE STOVE MANUFACTURER’S DESIGN. 

    MISHANDLING – OR ABUSE TO THE COMBUSTOR. A FEW EXAMPLES WOULD  BE … DROPPING IT, USING ABRASIVE TOOLS FOR CLEANING IT, USING HIGH PRESSURE AIR TO BLOW THE CELL FREE OF ANY FLY-ASH BUILD-UP, USING  CLEANING SOLVENTS TO CLEAN IT OR PERHAPS BEATING ON IT TO REMOVE IT FROM IT’S HOLDING DEVICE. 

    DIRECT FLAME IMPINGEMENT – FLAMES BURNING FOR LONG PERIODS OF TIME DIRECTLY INTO THE COMBUSTOR WITH THE BY-PASS OR DAMPER CLOSED WILL CAUSE THIS. ALLOWING THIS TO HAPPEN WILL CHANGE THE CHEMICAL MAKE-UP OF THE CATALYST AND CHANGE IT’S REACTION AS WELL. 

    FLAME IMPINGEMENT ON A CONTINUAL BASIS WILL CAUSE THE SUBSTRATE TO BREAK DOWN. SOME OF THE REASONS FLAME IMPINGEMENT OCCURS ARE OPERATING THE STOVE WITH THE FIREBOX DOOR AJAR OR THE ASH PAN NOT CLOSED TIGHTLY. OTHER REASONS MIGHT BE THAT THE DOOR GASKET NEEDS REPLACED OR THE AIR INTAKES ARE LEFT WIDE OPEN AFTER THE BY-PASS HAS BEEN CLOSED. UNCONTROLLABLE DRAW OR FAST DRAFT CAN BE CONTROLLED WITH THE USE OF A BAROMETRIC DAMPER. 

    POISONING – THIS HAPPENS BY BURNING MATERIALS OTHER THAN SEASONED DRIED WOOD. FOREIGN MATTER SUCH AS GARBAGE, PAINTED WOOD, LARGE AMOUNT OF COLORED PAPER, CARDBOARD, RUBBER, PLASTIC, PANELING WITH GLUE, OIL PRODUCTS AND SO ON WILL EVENTUALLY KILL THE EFFICIENCY OF THE CATALYST.

CATALYTIC COMBUSTOR CLEANING

NORMALLY THE CATALYTIC COMBUSTOR REQUIRES LITTLE OR NO MAINTENANCE. BECAUSE IT GENERATES SUCH HIGH TEMPERATURES, IT IS BASICALLY SELF-CLEANING. AFTER THE FIRST BURNING THE COMBUSTOR SHOULD HAVE A LIGHT GRAY POWDER-LIKE APPEARANCE.

SHOULD THE COMBUSTOR’S CELLS BECOME MASKED WITH FLY-ASH, USE A PAINTBRUSH OR SOFT-BRISTLED BRUSH AND DUST THE COMBUSTOR GENTLY. NEVER USE ANYTHING ABRASIVE TO CLEAN THE COMBUSTOR. A VACUUM CLEANER MAY BE USED, BUT NEVER USE HIGH PRESSURED AIR TO BLOW THE CELLS FREE OF ANY BUILD-UP. ANY CELL BLOCKAGE CAN BE REMOVED WITH THE USE OF A PIPE CLEANER OR A COTTON SWAB.

SHOULD THE COMBUSTOR BECOME MASKED WITH SOOT OR CREOSOTE, IT IS POSSIBLE TO BURN THE ACCUMULATION OFF BY OPENING THE BY-PASS AND BUILDING A HOT FIRE. ONCE THE HOT FIRE IS CREATED, CLOSE THE BY-PASS HALFWAY AND BURN FOR 30 – 60 MINUTES WITH THE BY-PASS IN THIS POSITION.

APPLIED CERAMICS SUGGESTS IT WOULD BE WISE TO CHECK AND CLEAN THE COMBUSTOR, IF NECESSARY, BEFORE EACH BURNING SEASON BEGINS.

WHY THE COMBUSTOR MIGHT STRUGGLE TO DO IT’S JOB

LIGHT-OFF - WAS NOT ACHIEVED BEFORE THE STOVE’S BY-PASS WAS  CLOSED. THIS MEANS THE CATALYST WAS NOT AT THE TEMPERATURE NECESSARY TO RECEIVE AND BURN THE INLET GASES. THIS WILL RESULT IN THE COMBUSTOR CELLS PLUGGING WITH FLY-ASH AND CREOSOTE. WHEN STARTING A FIRE IN A COLD STOVE, THE CATALYST NEEDS 500° F. OF TEMPERATURE FOCUSED ON IT FOR 20 – 30 MINUTES TO ALLOW PROPER LIGHT-OFF. 

    REFUELING - WET OR UNSEASONED WOOD WILL SHUT THE CATALYTIC  COMBUSTOR DOWN AT ONCE. THIS WILL RESULT IN THE COMBUSTOR’S CELLS    PLUGGING WITH FLY-ASH AND CREOSOTE. THIS WILL ALSO CAUSE THERMAL SHOCK TO THE COMBUSTOR’S SUBSTRATE AND HAIRLINE CRACKS WILL OCCUR ON THE  CELL WALLS. 

    MASKING – BLANKETING THE COMBUSTOR WITH A   SUBSTANCE THAT PREVENTS CATALYTIC ACTIVITY. 

    PLUGGING - A BUILD-UP OF SOOT, CREOSOTE AND/OR   FLY-ASH IN THE COMBUSTOR’S CELLS. THIS OCCURS WHEN THE COMBUSTOR IS OPERATED OR POSITIONED IMPROPERLY. INLET GAS TEMPERATURE MUST BE MAINTAINED AROUND 500°F.  TO KEEP THE CATALYST ACTIVATED. THIS ALSO OCCURS WHEN BURNING MATERIALS THAT PRODUCE LARGE FLAKES OR CHAR, LIKE WRAPPING PAPER OR CARDBOARD.

HOW TO MAINTAIN CATALYTIC BURNING CONDITIONS

WHEN INITIALLY STARTING UP A COLD STOVE, A MEDIUM TO HIGH FIRING RATE MUST BE MAINTAINED FOR 20 – 30 MINUTES. THIS WILL ALLOW THE  STOVE, THE CATALYTIC COMBUSTOR, AND THE FUEL TO STABILIZE AT A PROPER OPERATING TEMPERATURE EVEN THOUGH THE TEMPERATURE CAN REACH 600° F. WITHIN A FEW MINUTES AFTER THE FIRE HAS STARTED. IF THE FIRE IS TURNED  DOWN TOO SOON TO A LOW BURNING CONDITION, IT WILL RESULT IN THE FIRE AND/OR THE CATALYTIC COMBUSTOR GOING OUT.

AT THE END OF A BURN CYCLE, IT’S POSSIBLE THAT THE AMOUNT OF BURNING EMBERS REMAINING MIGHT NOT PROVIDE SUFFICIENT TEMPERATURE OR FUEL FOR THE CATALYST TO STAY LIT.

DURING THE REFUELING OF A HOT STOVE THAT HAS AN INTERNAL TEMPERATURE BELOW 500° F., IT IS BEST TO FIRE THE STOVE UP FOR 10 – 15 MINUTES TO ENSURE SUFFICIENT TEMPERATURE AND PROPER AMOUNTS OF VOLATILE GASES FOR THE CATALYST TO OPERATE WELL AND EFFICIENTLY. HOWEVER, WHEN REFUELING A HOT STOVE THAT HAS AN INTERNAL TEMPERATURE ABOVE 500°F., NO REFIRING IS NECESSARY.

CATAYTIC COMBUSTOR TEMPERATURES

COMBUSTOR TEMPERATURES CAN BECOME EXTREMELY HOT DURING OPERATION. TEMPERATURES ABOVE 1800° F. WILL DAMAGE THE CATALYST. TEMPERATURES BETWEEN 1400°F. AND 1600° F. ARE NORMAL, BUT TEMPERATURES BETWEEN 1200° F. AND 1400° F. ARE RECOMMENDED.